Patient Monitor S12
Patient Monitor S12
 
Patient Monitor S12
 

Patient Monitor S12

 Patient monitors are used for continuous monitoring of vital signs

Patient monitor S12 is designed for continuous monitoring, display, viewing, and storage of various physiological parameters in adults, children, and neonates: electrocardiogram (ECG), heart rate (HR), respiratory rate (RR), temperature (TEMP), blood oxygen saturation (SpO2), pulse rate (PR), noninvasive blood pressure (NIBP), capnography (CO2), invasive blood pressure (IBP), and cardiac output (CO).

A compact, convenient, and easy-to-use patient monitor is ideal for use in medical facilities, private clinics, outpatient clinics, treatment and postoperative rooms, and emergency departments.

The S series patient monitors are based on Biolight's many years of experience in developing and manufacturing innovative world-class medical devices.

 

 FEATURES

  • Portable design with hidden handle
  • 12.1” color TFT LCD display
  • Screen resolution: 800x600 pixels
  • Operating time  from rechargeable Li-ion battery  > 240 min
  • Data storage: 72 hours of holographic waveform
  • Size: 175 mm x 320 mm x 262 mm
  • Weight: < 4kg

 

PARAMETERS:

ECG: 

Patient monitor provides 3-, 5-, 6-, and 12-lead ECG monitoring, arrhythmia analysis, ST segment analysis, and QT/QTc measurement.

3 lead: I, II, III

5 lead: I, II, III, aVR, aVL, aVF, Vx

6 lead: I, II, III, aVR, aVL, aVF,Va, Vb

12 lead: I, II, III, aVR, aVL, aVF,V1~V6

Auto: identify leads automatically

Recognition of 27 types of arrhythmias

 

NIBP:

Measurement way: Automatic oscillometry

Measurement mode: Manual , Auto, STAT

Intervals for Auto measurement: 1/2/2.5/3/5/10/15/20/30min, 1/1.5/2/4/8 h

STAT mode cycle time 5 minutes

Measurement range:

Systolic range: Adult: 30 ~ 270 mmHg, Pediatric: 30 ~ 235 mmHg, Neonatal: 30 ~ 135 mmHg

Diastolic range: Adult: 10 ~ 220 mmHg, Pediatric: 10 ~ 220 mmHg, Neonatal: 10 ~ 110 mmHg

Mean range: Adult: 20 ~ 235 mmHg, Pediatric: 20 ~ 235 mmHg, Neonatal: 20 ~ 125 mmHg

Cuff pressure range: 0 to 300 mmHg

 

 SpO2:

Non-invasive method of measuring arterial blood oxygen saturation

Діапазон вимірювання: 0% ~ 100%

PR

Measurement range: 25 - 300 bpm

PI

Measurement range:  0.05~20.00%

RESP (from pleth)

Measurement range: 0 ~90 rpm

 

TEMP:

Parameter: T1,T2, TD

Measurement range: 0.0℃ to 50.0℃(32℉ to 122℉)

 

IBP - only for models: Patient Monitor S12 with 2-IBP module

Sensitivity of transducer : 5uV/V/ mmHg, ±2%

Impedance of transducer: 300Ω to 3000Ω

Measurement range: -50 mmHg to +360 mmHg

  

Mainstream СО2 - only for models: Patient Monitor S12 with Mainstream ETСO2 module C6

Method: Infrared absorption technology

Measurement range: 0% ~ 25%

 

  

Producer: Guangdong Biolight Meditech Co., Ltd, China

 

 

 

 

Ready to work with us?

Contact with our team to leave your request or proposal

Contact us

 

logo Our managers are waiting your request

 

© Copyright 2023 Medical devices
Alenta Medical. All Rights Reserved.

  • Home
  • About us
  • Catalog
    • Diagnosis equipment
    • Intensive therapy
    • Neonatology
    • Operating light, Operating tables
    • Medical furniture
    • Infusion therapy
  • Brands
  • Contacts

In order to provide you with the best online experience this website uses cookies.

By using our website, you agree to our use of cookies. Learn more

I agree